Instalacion
78
Conexion de Gas e Arranque Inicial
Tipo de
Gas
Presión de
Entrada,
mbaras
Presión del
Quemador,
mbaras
Diámetro
del inyector,
mm
Abertura
de Aire,
mm
Inyector
del Piloto
mm
Valor de Entrega
Estándar,
kW (H
i
)
961-P, 966, 981
G25 25 18 3.20 4 .45 14.6 Gas na t u ral
G20 20 12 3.20 4 .45 14.6 Gas na t u ral
G20/G25 20/25 --- 2.90 8 .45 14.6 Gas nat ural
951, 961
G25 25 18 2.70 10 .45 11. 1 Gas natural
G20 20 12 2.70 10 .45 11. 1 Gas natural
G20/G25 20/25 --- 2.50 10 .45 11.1 Gas na t u ral
1048-BL, 1060-BL
G25 25 12 3.35 9 .45 24.9 Gas na t u ral
G20 20 8 3.35 22 .45 24.9 Gas natural
G20/G25 20/25 --- 2.80 10 .45 24.9 Gas na t u ral
G30 30/50 17 2.05 30 0.25 24. 9 Buta n o
G31 30/37/50 24 2.05 30 0.25 24. 9 Propano