Installation
8
Gas Connection and Initial Startup
Type of
Gas
Inlet
Pressure
mbars
Burner
Pressure
mbars
Injector
Diameter
mm
Air
Opening
mm
Pilot
Injector
mm
Standard
Delivery
Value kW (H
i
)
961-P, 966, 981
G25 25 18 3.20 4 .45 14.6 Natural Gas
G20 20 12 3.20 4 .45 14.6 Natural Gas
G20/G25 20/25 --- 2.90 8 .45 14.6 Natural Gas
951, 961
G25 25 18 2.70 10 .45 11.1 Natural Gas
G20 20 12 2.70 10 .45 11.1 Natural Gas
G20/G25 20/25 --- 2.50 10 .45 11.1 Natural Gas
1048-BL, 1060-BL
G25 25 12 3.35 9 .45 24.9 Natural Gas
G20 20 8 3.35 22 .45 24.9 Natural Gas
G20/G25 20/25 --- 2.80 10 .45 24.9 Natural Gas
G30 30/50 17 2.05 30 0.25 24.9 Butane
G31 30/37/50 24 2.05 30 0.25 24.9 Propane