Page view 11
Installation
8
Electrical Connection
Wiring diagrams are located in the control
compartment and on the back of the oven.
The electric motor, indicator lights and related
switches are connected to the oven as follows:
1. Remove the bottom trim and control panel
covers. Slide the control panel forward.
2. Connectthesupplyconduittothewireductlo-
cated in the lower left hand corner on t he back
of the oven.
3. Run the supply wires through the duct to the
front of the oven.
4. Connect the supply wires to top of right con-
tactor in the control compartment at the lower
right corner of the oven.
5. Reinstall the bottom trim and control panel
covers.
NOTE: To prevent damage there is no power to
the heating elements when the blower is
not operating.
THE BLODGETT O VEN COMPANY CANNOT AS-
SUME RESPONSIBILITY FOR LOSS OR DAMAGE
SUFFERED AS A RESULT OF IMPROPER INSTAL-
LA TION.
Install incoming
power on this
contactor