2.2 WALL EXHAUST FAN:
The exhaust fan should be installed at least two feet above the vent opening at the
top of the unit.
2.3 CLEARANCES:
Adequate clearance must be provided in aisle and at the side and back. Adequate
clearances for air openings into the combustion chamber must be provided, as well as
for serviceability for use on noncombustible floors. Minimum clearance from
combustible and noncombustible construction, 3 inches on left side, 8 inches on right
side and 6 inches from back.
TO INSTALL:
1. Uncrate carefully. Report any hidden freight damage to the freight company
immediately.
2. Set the unit in place. Be certain to maintain the minimum clearances from
combustibles and non-combustibles.
3. Level appliance using spirit level. Should flanged adjustable feet be provided,
anchor to floor using proper anchoring devices.
4. Seal bolts and flanged feet with Silastic or other equivalent compound.
5. Be certain to leave adequate clearances for cleaning, maintenance and service.
WARNING: These procedures must be followed by qualified personnel or warranty will be
voided. An open gap floor drain is required immediately below the appliance drain.